Solutions

Calibrators

  • air sa
  • calibrators
  • mems
  • nbsp
  • pumps&
  • sound level m

[ Casella Solutions ]

CEL-120

  • Best Selling
  • Hardware
  • Software
  • Transmission
  • Parameters

OVERVIEW The Casella 120 Acoustic Calibrator is the smallest of its type in the world; with a rugged, over-moulded design for use in field environments. The field calibration of Sound Level Meters is an essential procedure when carrying out any type of noise survey both before and after each measurement sequence. This ensures that instruments are providing consistently accurate readings necessary for monitoring to ensure compliance with workplace and environmental noise regulations. The 120 is therefore designed and manufactured to comply with the requirements of IEC 60942: 2003 and ANSI S1.40: 2006. These standards stipulate accurate calibration over a wide range of temperature, humidity and pressure conditions, typical of field work, ensuring accurate calibration in all conditions. The Casella 120 Acoustic Calibrator callibrate the 24x Series Sound Level Meter. DIGITAL TECHNOLOGY FOR OPTIMUM ACCURACY The 120 is compact and ergonomically designed with simplicity and ease of use being the highest priorities. Key features include a simple keypad for intuitive control, permitting calibration level changes when required. When used with instruments like the-62X series, calibration routines commence automatically as soon as a calibration tone is detected to further simplify the task. The 120 uses a MEMS microphone and a digital feedback loop to maintain the acoustic pressure in the cavity at the required level. An indicator shows if the sound level meter microphone is incorrectly inserted into the cavity, removing any potential for calibration error. The microprocessor control detects when the microphone is removed and automatically switches off the calibration tone. This conserves battery power, allowing batteries to last for up to 2 years of operation. Both the CEL-120/1 and CEL-120/2 calibrator accept all industry standard 1/2“ microphone capsules. Smaller 1/4“ microphones may be accommodated using the 1/2“ to 1/4“ adaptor (CEL-4726). The relevant 120 also comes as standard with our range of noise monitoring kits.

More info

[ Casella Solutions ]

Flow Detective - Digital Air Flow Meter

  • Best Selling
  • Hardware
  • Software
  • Transmission
  • Parameters
  • pumps 
  • calibrators
  • air sampling

The Flow Detective is the first sampling pump airflow calibrator to measure pulsation for ISO 13137 compliance. The device displays a red indicator if pulsation the 10% compliance level is exceeded. It measures the flow of air sampling pumps to within 2% accuracy and when used with the Casella Apex2, it can achieve closed loop automatic calibration, so nothing has to be set manually.

More info

[ Leyro instruments ]

LBB 90

  • Best Selling
  • Hardware
  • Software
  • Transmission
  • Parameters

Leyro Instruments has developed a precision Black Body Calibrator for real time measurement, to give a quick response to manufacturers of IR thermal imaging cameras. With the current COVID-19 Pandemic spreading around the world. The BLACK BODY by Leyro allows the detection of fever by comparison, which allows an immediate and non-invasive response in people. The LBB 90 provides a point of comparison and greater accuracy in measurement, together with IR thermal imaging cameras and that can help in Hotels, Hospitals, large commercial areas, factories, airports, train stations, or any space with high traffic of people, to prevent the spread of the disease. The Black Body (BLACK BODY) of Leyro LBB 90 allows to avoid any error or drift in the measurement on the reference point, in the field of view of the thermal imager. This equipment has been specially designed for this purpose, providing a real and precision reading point, compatible with all cameras on the market, allowing it to be used 24/7.

More info

[ Leyro instruments ]

LCB 30-Portable Temperature calibrator micro bath

  • Best Selling
  • Hardware
  • Software
  • Transmission
  • Parameters

Portable thermostatic temperature Calibration bath. THE FASTER IN THE WORLD. Temperature range -35ºC… 165ºC. It offers an accuracy of 0,3ºC in all the temperature range, a depth of inmersion of 190 mm and a diameter of 60 mm.

More info

[ Leyro instruments ]

LHC 650

  • Best Selling
  • Hardware
  • Software
  • Transmission
  • Parameters

Leyro portable temperature dry well LHC 650 for temperature calibrations between +40 ºC… 650 ºC. With a stability of ±0,1ºC, an uniformity of ±0,1 ºC and an accuracy of ±0,2 ºC , it offers a versatile solution for calibrating thermocouples in all kind of industrial environments, offering excellent results and a fast response time. The LHC 650 is easy to use thanks to its compact and light design. Thanks to big size of the insert, it has a big drilling capacity and can calibrate a lot of thermocouples at the same time. Apart from the standard insert (B) you can choose different types of optional inserts, so the equipment can be adapted to any circumstances

More info

[ Leyro instruments ]

LHC 75

  • Best Selling
  • Hardware
  • Software
  • Transmission
  • Parameters

Leyro portable temperature dry well LHC 400 for temperature calibrations between +40 ºC… 375 ºC. With a stability of ±0,05ºC, an uniformity of ±0,2 ºC and an accuracy of ±0,3 ºC , it offers a versatile solution for calibrating thermocouples in all kind of industrial environments, offering excellent results and a fast response time. The LHC 75 is easy to use thanks to its compact and light design. Thanks to big size of the insert, it has a big drilling capacity and can calibrate a lot of thermocouples at the same time. Apart from the standard insert (A) you can choose different types of optional inserts, so the equipment can be adapted to any circumstances.

More info

[ Leyro instruments ]

LHC40

  • Best Selling
  • Hardware
  • Software
  • Transmission
  • Parameters

Leyro's portable dry block temperature calibrator for temperature calibrations between -35ºC… 165ºC *. With ± 0.03ºC stability, ± 0.05ºC uniformity and ± 0.3ºC accuracy, it offers a versatile solution for calibrate thermocouples in industrial environments, offering excellent performance as well as fast response time. The LHC 40 is easy to use, thanks to its compact and lightweight design. Thanks to the large size of the insert, it has a large drilling capacity and can calibrate a large number of thermocouples at the same time. In addition to the standard insert (A), it has several types of optional inserts (B, C, D, E) to adapt to any need.

More info

[ MMF - Metra ]

VC20

  • Best Selling
  • Hardware
  • Software
  • Transmission
  • Parameters

- Quick and simple calibration and fault detection of sensors and measuring chains for acceleration, velocity and displacement - Load independent vibration magnitude - Vibration magnitude of 10 m/s² (VC20) or selectable in 5 steps from 1 to 20 m/s² (VC21) - Quartz stabilized vibration frequency of 159.2 Hz (VC20) or selectable in 7 steps from 15.92 Hz to 1280 Hz (VC21) - Suitable for the calibration of whole-body human vibration meters to ISO 8041 and building vibration meters to DIN 4150-3 - Battery operated for mobile use - Traceable to PTB reference standard - Rugged design

More info

[ MMF - Metra ]

VC21

  • Best Selling
  • Hardware
  • Software
  • Transmission
  • Parameters

- Quick and simple calibration and fault detection of sensors and measuring chains for acceleration, velocity and displacement - Load independent vibration magnitude - Vibration magnitude of 10 m/s² (VC20) or selectable in 5 steps from 1 to 20 m/s² (VC21) - Quartz stabilized vibration frequency of 159.2 Hz (VC20) or selectable in 7 steps from 15.92 Hz to 1280 Hz (VC21) - Suitable for the calibration of whole-body human vibration meters to ISO 8041 and building vibration meters to DIN 4150-3 - Battery operated for mobile use - Traceable to PTB reference standard - Rugged design

More info

[ Svantek ]

SV 33 Class 1 Acoustic Calibrator

  • Best Selling
  • Hardware
  • Software
  • Transmission
  • Parameters
  • calibrators
  • mems
  • sound level meters
  • dosimeters

- Class 1 sound calibrator IEC 60942 - Frequency 1 kHz - 114 dB level - Internal reference MEMS microphone - Automatic power off

More info

[ Svantek ]

SV 34 Class 2 Acoustic Calibrator

  • Best Selling
  • Hardware
  • Software
  • Transmission
  • Parameters
  • calibrators
  • mems
  • sound level meters
  • dosimeters
  • microphones

- Class 2 sound calibrator IEC 60942 - Frequency 1 kHz - 114 dB level - Internal reference MEMS microphone - Automatic power off

More info

[ Svantek ]

SV 35 Acoustic Calibrator

  • Best Selling
  • Hardware
  • Software
  • Transmission
  • Parameters
  • calibrators

- SV 35 & SV 33 class 1 sound calibrators meeting IEC 60942:2003 - SV 34 class 2 sound calibrator meeting IEC 60942:2003 - Frequency 1 kHz ? - 94 dB or 114 dB levels (SV 35) - 114 dB level (SV 33, SV 34) - Built-in reference microphone SV 35 Class 1 Acoustic Calibrator produces an acoustic pressure of defined level 94 db & 114 dB at frequency of 1 kHz.

More info

[ Svantek ]

SV111

  • Best Selling
  • Hardware
  • Software
  • Transmission
  • Parameters

Portable Vibration Calibrator: SV 111 is a multi-frequency vibration calibrator designed for in-situ checks according to ISO 8041. The SV 111 is suitable for calibration checks of various types of vibration meters at different frequencies from 16 Hz up to 640 Hz. Depending on the selected frequency user may select level of calibration from 1 m/s2 to 10 m/s2. Shaker can be loaded with large weight up to 1 kilogram at 16 Hz. The design of the calibrator is based on the built-in triaxial reference accelerometer and microprocessor-controlled shaker. Following ISO 8041 requirement the reference accelerometer measures the cross-axis / transverse vibrations to detect interference on the calibration signal. Faults caused by transverse vibrations are indicated by three LEDS on the calibrator’s panel. This unique solution ensures the excellent stability of the calibration level & frequency independently from mass of the testing object. For calibration checks of tri-axial sensors set of dedicated adapters is available including a special adapter to Svantek whole-body sensors (seat-pads) for direct mounting on the shaker. Other types of vibration transducers can be conveniently attached using mounting stud, mounting disc or dedicated adapter.

More info